品牌: Belden百通
产品详细参数:
芯数: 统轴 线规(AWG): 14 屏蔽材料: 箔片 60%铝编制 Duofoil 40%铝编织 额定核心外径(MM): 10.34 标准包装长度: 305米/卷
General Description:
14 AWG solid bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond. IV quad shield (100% coverage), PVC Jacket.
Usage (Overall)
Suitable Applications: RG-11/U Type
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (in.)
1 14 Solid BCCS - Bare Copper Covered Steel .064
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (in.)
Gas-injected FPE - Foam Polyethylene .280
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Duofoil. Tape Bonded Aluminum Foil-Polyester 100
Tape-Aluminum Foil
2 Braid AL - Aluminum 60
3 Duofoil. Tape Aluminum Foil-Polyester 100
Tape-Aluminum Foil
4 Braid AL – Aluminum 40
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 0.407 in.
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +80°C
Bulk Cable Weight: 59 lbs/1000 ft.
Max. Recommended Pulling Tension: 308 lbs.
Min. Bend Radius/Minor Axis: 4.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL2R, CMR
CEC/C(UL) Specification: CMG
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
RG Type: 11/U
Flame Test
UL Flame Test: UL1666 Riser
CSA Flame Test: FT4
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 3095A
Surface Printing (Overall)
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm) Tolerance (Ohms)
75 ± 3
Nom. Inductance:
Inductance (μH/ft)
.097
Nom. Capacitance Conductor to Shield:
Capacitance (pF/ft)
16.2
Nominal Velocity of Propagation:
VP (%)
82
Nominal Delay:
Delay (ns/ft)
1.2
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
11.0
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
1.5
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
1 .16
2 .18
5 .26
10 .38
20 .55
50 .83
100 1.17
200 1.60
300 1.99
400 2.30
Max. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
1 .33
2 .35
5 .44
10 .66
20 .78
50 .99
100 1.32
200 1.87
300 2.29
400 2.64
Max. Operating Voltage - UL:
Voltage
300 V RMS
Minimum Structural Return Loss:
Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB)
5 400 20
Notes (Overall)
Notes: Sweep tested 5 to 400 MHz. Tap marks every 2.6 Meters to aid users in installation.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
3094A F2V1000 1,000 FT 67.000 LB GRAY, DEC #14 GIFHDLDPE DSH PVC
3094A F2V2000 2,000 FT 136.000 LB GRAY, DEC C #14 GIFHDLDPE DSH PVC
3094A F2V500 500 FT 34.500 LB GRAY, DEC #14 GIFHDLDPE DSH PVC
Notes:
C = CRATE REEL PUT-UP.
获取更多产品讯息或帮助,请联系我们--上海深恩工业